Reeb Price Catalog - Exterior Doors - Effective 05/20/2024
Therma-Tru Additions and Deductions
Outswing Unit Dimensions All dimensions on this page reflect 6’8” units using a composite outswing sill with a Unit Height of 81-3/16” and a Rough Opening Height of 81-11/16”.
Single Unit
Double Door 7/8” Astragal
Rough Opening Width
Description Unit Size Width
Rough Opening Width
Description Unit Size Width
10" sidelite 12" sidelite 14" sidelite
11-1/2" 13-1/2" 15-1/2" 25-5/8" 29-5/8" 31-5/8" 33-5/8" 35-5/8" 37-5/8" 43-5/8"
12-1/4” 14-1/4” 16-1/4” 26-3/8” 30-3/8” 32-3/8” 34-3/8” 36-3/8” 38-3/8” 44-3/8”
4'8" 5'0" 5'4" 5'8" 6'0"
58-9/16" 62-9/16" 66-9/16" 70-9/16" 74-9/16"
59-5/16" 63-5/16" 67-5/16" 71-5/16" 75-5/16"
2'0" 2'4" 2'6" 2'8" 2'10"
3'0" 3'6"
Continuous Single Unit with One Sidelite Standard Mullion
Continuous Single Unit with Two Sidelites Standard Mullion
Rough Opening Width
Rough Opening Width
Description Unit Size Width
Description Unit Size Width
3'0" w/ 10" s/l 3'0" w/ 12" s/l 3'0" w/ 14" s/l
48-5/8" 50-5/8" 52-5/8"
49-3/8” 51-3/8” 53-3/8"
3'0" w/ 10" s/l 3'0" w/ 12" s/l 3'0" w/ 14" s/l
59-5/8" 63-5/8" 67-5/8"
60-3/8" 64-3/8" 68-3/8"
Patio Door Standard Mullion
Triple Patio Door Standard Mullion
Rough Opening Width
Rough Opening Width
Description Unit Size Width
Description Unit Size Width
4'8" 5'0" 5'4" 5'8" 6'0"
58-13/16" 62-13/16" 66-13/16" 70-13/16" 74-13/16"
59-9/16" 63-9/16" 67-9/16" 71-9/16" 75-9/16"
7'0" 7'6" 8'0" 8'6" 9'0"
88" 94"
88-3/4" 94-3/4" 100-3/4" 106-3/4" 112-3/4"
100" 106" 112"
6’6” doors: deduct 2” from the height 7’0” doors: add 4” to the height. 8’0” doors: add 16” to the height.
Public Access Sills: for a 6’8” unit, the UD height is 81”, the RO height is 81-1/2” Outswing Bumper Sill: for a 6’8” unit, the UD is 80-5/8, and the RO is 81-1/8” 7/4 Outswing SIll: for a 6’8” unit, Doors will be trimmed for a UD height of 82”, and RO height of 82-1/2” Coastal Outswing Sill: for a 6’8” unit, the UD is 80-5/8” and the RO is 81-1/8” Dimension Adders Rough Opening (the opening in a standard wall): add 3/4” to the Unit Width and 1/2” to the Unit Height Brickmould Dimension (from edge of brickmould to edge of brickmould): add 3” to the Unit Width and 1-1/2” to the Unit Height Masonry Opening (the opening in a masonry wall): add 3-1/2” to the Unit Width and 1-3/4” to the Unit Height Boxed Unit (individual units mulled together): Add each unit dimension together, then add 3/4” to the Width for the Rough Opening Transoms (glass component on top of the unit): Add door unit and transom unit dimensions together, then add 1/2” to the Height for the Rough Opening
Therma-Tru Adds & Deducts - Page 4 1Q2022 Visit our online catalog at reeb.com/pricecatalog
Made with FlippingBook flipbook maker